Hosting by |
TECHNICAL SPECIFICATIONS Conforming to standards: CEI EN 60947-1, CEI EN
60947-5-1, CEI EN 60529, CEI EN 60204-1 (for CE), UL 508 (for UL). Certifications: CE Certification: UL Listed to Canadian and U.S. safety standards Ind. Cont. Eq.: auxiliary device listed 2HD8 Ambient temperature: storing
–40°C +70°C Ambient temperature: working –20°C +70°C Protection level: IP 65 according to CEI EN 60529 Insulation class: class I according to IEC 536 All metal shell: zamak. Four directions orientable actuators. Models with roller actuators are provided for
working: Both clockwise and anti clockwise (standard version) Clockwise only Anti clockwise only TECHNICAL SPECIFICATIONS OF THE CONTACT ELEMENTS Certifications: CE Certification: UL Listed to Canadian and U.S. safety standards Ind. Cont. Eq.: auxiliary device listed 2HD8 Positive Opening 1NO+1NC contact block. Nominal thermic current: 10A according to CEI EN 60947-5-1 Electrical rating: A600 Q600 (UL 508) Nominal insulating voltage: 300V~ (CEI EN 60947-5-1) Mechanical duration: 10.000.000 maneuver (107 cycles) Maneuver frequency: 50¸60 man. each minute (up to 1 Hz) Identification of terminals: According to CENELEC EN 50013 Prot. Vs short circuits: Cartridge fuse
10A (CEI EN 60947-5-1) Wire size (stranded or solid): 1x14¸18 AWG or 2x16¸18 AWG 60-75°C Cu (copper) Cond. - Torque: 0,75 Nm Fast kick silver contacts Maximum working voltage 500V~ Nominal magnitude of current: 16A at 250V~
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
E-Mail: stz@stzsrl.it |
S.T.Z. s.r.l. Strada delle Brigole n° 2/A 23877 Paderno d’Adda (LC) Italy Tel: 0039 039 514038 Fax: 0039 039 514044 |